Skip to main content
ValveTraceLicence-checked valve sourcing

BS 6364 vs ISO 28921-1: what a cryogenic test proves

Guide · BS 6364 · ISO 28921-1 · Cryogenic valves

BS 6364 and ISO 28921-1 both address valves for low-temperature service, but they answer different questions. BS 6364 is the British Standard with a cryogenic type test that qualifies a design. ISO 28921-1 covers design, manufacturing and production testing of isolating valves. Name the standard, edition and report your order requires.

01

What each standard covers

BS 6364 is a British Standard for valves in cryogenic service. It sets design requirements and a low-temperature type test, and buyers name it in a purchase order when they want a valve design qualified at cryogenic temperature.

ISO 28921-1 is the international standard for isolating valves in low-temperature applications. Part 1 covers design, manufacturing and production testing, and it is written around the valves supplied in an order rather than only around a representative design.

Neither document is a certificate in itself. They are specifications: a report states which standard, edition and test conditions were used, and that statement is what you compare with your purchase order.

02

The two standards side by side

The table summarises how the two documents are normally used in a valve order. Test temperature, tracer gas and acceptance limits are defined by the edition named in the purchase order, so read that edition before you compare reports.

BS 6364 and ISO 28921-1 compared: what each document is used for in a valve order
QuestionBS 6364ISO 28921-1
What it isBritish Standard for valves in cryogenic serviceInternational standard for isolating valves in low-temperature applications; Part 1 covers design, manufacturing and production testing
Usual role in a purchase orderType-test report for a valve designDesign and production-test specification for the valves supplied
Test temperatureMinimum design temperature of the valve; liquid nitrogen at about −196 °C for the lowest ratingsMinimum design temperature agreed for the order; the report records the temperature reached
Leak-test mediumHelium tracer gas with a mass spectrometerTracer gas with a mass spectrometer; helium is the usual medium
Leakage resultMeasured leak rate against the limit in the standardMeasured leak rate against the limit in the standard or the order
What the report coversA design and the size and class range named in itThe valves in the order and their production test records
03

The test temperature follows the valve, not the standard title

A cryogenic test is run at the valve’s minimum design temperature, or at the test temperature agreed in the order. Liquid nitrogen at about −196 °C is the usual bath for LNG and liquid-nitrogen service, but a valve rated to a warmer minimum, such as −46 °C, is not automatically tested at −196 °C.

The report must record the temperature actually reached, how it was measured and how long the valve was held at temperature. A report that says only “cryogenic tested” cannot be compared with a specification.

04

Helium is the test medium for the leak measurement

Cryogenic leak tests use a tracer gas and a mass spectrometer rather than a water bath and a bubble count. Helium is the usual tracer because its small molecule passes small leaks, and the spectrometer measures the rate directly.

A hydrostatic shell test in water and a helium leak test answer different questions. The shell test proves strength at ambient temperature; the helium test shows how tight the seat and body seals are when the valve is cold.

05

Leakage is a measured rate, not a bubble count

The result of a cryogenic leak test is a rate, measured with a mass spectrometer and compared with a limit in the standard named in the order. Rates are reported in units such as mbar·l/s or cm³/s, and the record should state the unit, the gas, the test pressure and the acceptance limit.

Do not compare that rate with the bubble count or “no visible leakage” wording of an ambient seat test. They are different tests with different limits, and a lower number in one does not prove the other.

Ask for the test record for the serial number in the order, not only a summary certificate. It should identify the instrument and its calibration, the temperature, the pressure, the measured rate and the pass limit.

06

Type testing and production testing are not interchangeable

A type test qualifies a design. One representative valve, or a range agreed in the test programme, is tested at low temperature, and the report then covers the sizes, classes and seat designs it names. It says nothing about the individual valve in your order.

Production testing is applied to the valves you buy: shell and seat tests at ambient temperature, a functional or operating-torque check where the standard requires it, and any low-temperature test the order adds. Each valve gets its own record with its serial number.

An order that needs both should say so: a BS 6364 type-test report for the design and production test records for each valve. One does not replace the other.

07

Frequently asked questions

Is BS 6364 the same as ISO 28921-1?
No. They are separate standards with overlapping scope. BS 6364 is the British Standard for cryogenic valves with a low-temperature type test; ISO 28921-1 is the international standard for isolating valves in low-temperature applications, covering design, manufacturing and production testing. A report to one does not automatically satisfy a specification that names the other.
At what temperature is a BS 6364 test run?
At the valve’s minimum design temperature. Liquid nitrogen at about −196 °C is used for the lowest ratings, and a valve rated for a warmer minimum is tested at its own rating. The report must state the temperature actually reached.
Why is helium used for cryogenic leak testing?
Helium has a small molecule and passes leaks that a water or air test may not show, and a mass spectrometer measures the leakage rate precisely. That produces a number that can be compared with a limit, instead of a bubble count.
Does a type test cover every valve in my order?
No. A type test qualifies a design and the size and class range named in the report. Each valve still needs its own production test record: shell, seat and functional tests, plus any low-temperature test your order adds.
Which standard should I put in the purchase order?
Name the standard and edition your project specification requires, and say which reports you want: a type-test report for the design, production test records for each valve, or both. If the project allows either standard, state which one governs if the two documents disagree.
08

Standards cited

  • BS 6364: Valves for cryogenic service: design requirements and a low-temperature type test. Edition quoted to: BS 6364:1984 (withdrawn by BSI in 2021 but still named in many LNG specifications).
  • ISO 28921-1: Isolating valves for low-temperature applications: design, manufacturing and production testing. Edition quoted to: ISO 28921-1:2022 (BS EN ISO 28921-1:2022).
09